電(dian)(dian)磁(ci)(ci)閥(fa)產品的(de)接(jie)線(xian)(xian)較為簡單,一般電(dian)(dian)磁(ci)(ci)閥(fa)的(de)電(dian)(dian)源線(xian)(xian)有地線(xian)(xian)、正(zheng)極(ji)和負極(ji)三根線(xian)(xian),如果是交流電(dian)(dian),接(jie)線(xian)(xian)的(de)正(zheng)負極(ji)則可(ke)以不必考慮,如果是直流電(dian)(dian),就需要(yao)注意正(zheng)負極(ji),并(bing)且要(yao)注意電(dian)(dian)壓(ya)要(yao)相同(tong)。電(dian)(dian)磁(ci)(ci)閥(fa)具體的(de)接(jie)線(xian)(xian)圖如下(xia):
電磁閥工作原理(li)及接線(xian)圖
1、先(xian)要檢查(cha)電(dian)磁(ci)閥是(shi)否與選(xuan)型參數一致,比如電(dian)源電(dian)壓(ya)(ya)(ya)、介質壓(ya)(ya)(ya)力、壓(ya)(ya)(ya)差等,尤(you)其是(shi)電(dian)源,如果搞(gao)錯,就會(hui)燒(shao)壞線圈。電(dian)源電(dian)壓(ya)(ya)(ya)應滿足額定電(dian)壓(ya)(ya)(ya)電(dian)壓(ya)(ya)(ya)波動范(fan)圍:交流+10%~-15%,直流+10%~-10%,平時線圈組(zu)件(jian)不宜拆開。
2、接(jie)管之前要對管道進行沖洗,把管道中(zhong)的金屬粉末及密封材料(liao)殘留(liu)物,銹垢等(deng)清(qing)除。要注意介質(zhi)(zhi)的潔(jie)凈度,如(ru)果介質(zhi)(zhi)內混有(you)塵垢,雜(za)質(zhi)(zhi)等(deng)妨礙電(dian)磁閥(fa)的正常工作,管道中(zhong)應裝過濾器或濾網。
3、一般電(dian)磁閥的電(dian)磁線圈部件應豎直向(xiang)上(shang),豎直安裝(zhuang)在(zai)水平(ping)于(yu)地面的管道,如果受空間限制或工況要求必(bi)須按側立安裝(zhuang)的,需在(zai)選型訂貨時提出(chu)。否(fou)則可能造成電(dian)磁閥不能正常工作。
4、電(dian)磁閥前后應加(jia)手(shou)動切斷(duan)閥,同時應設旁路,便于電(dian)磁閥在故障時維(wei)護(hu)。
5、電磁閥(fa)一般是(shi)定向(xiang)的,不可裝反,通常(chang)在(zai)閥(fa)體上用→指(zhi)出(chu)介質流動方向(xiang),安裝時(shi)要(yao)依照→指(zhi)示的方向(xiang)安裝。不過在(zai)真空管路或(huo)特殊(shu)情況下可以(yi)反裝。
6、如果介質(zhi)會起水(shui)錘現象,那么應(ying)(ying)該(gai)選用具防(fang)水(shui)錘功能的(de)(de)電磁(ci)閥或采取相應(ying)(ying)的(de)(de)防(fang)范措施。
7、盡量(liang)不(bu)要讓電磁閥長時(shi)間處于通電狀態(tai),這樣容易(yi)降(jiang)低線(xian)圈(quan)使(shi)用壽命甚至燒壞線(xian)圈(quan),就是說,常開、常閉(bi)電磁閥不(bu)可互換使(shi)用。
8、蒸汽用電磁(ci)閥入口側應裝(zhuang)有(you)疏水閥,該處接(jie)管應傾斜。

dgfmjt@163.com

021-66861950

上海(hai)市金山區亭林鎮亭朱公路1918號